Search

Studies in Skin Perfusion Dynamics : Photoplethysmography and its Applications in Medical Diagnostics | 1:a upplagan

av Vladimir Blazek och Jagadeesh Kumar V.

Köp begagnad bok

Ej i lager. Bevaka denna bok.

Köp ny bok

Fakta

Förlag Springer Nature
Språk Engelska
Bandtyp Inbunden
Utgiven 2021-02-16
Upplaga 1
Antal sidor 216
ISBN 9789811554476
Kategori(er)
Lägg i varukorgen

Beskrivning

This book talks about photoplethysmography (PPG) techniques based on computer-aided data processing. In particular, it presents the results of a co-operative Indo-German project on the topic between Indian Institute of Technology at Chennai and RWTH Aachen University. Measuring system design, experimental details and some preliminary results obtained so far within the framework of this project are presented here. From the investigations carried out so far using the PPG sensors in conjunction with breathing sensors, it has been possible to monitor the 0.125 to 0.15 Hz rhythms in the arterial volumetric changes and to study the influence of breathing on them. These rhythms, which according to medical experts have relevance to psychosomatic conditions e.g. stress or relaxation, can also be addressed to by ancient Indian practices like yoga and meditation. This book presents the results of studying the effects of Indian relaxation techniques like pranayama, meditation, etc. in comparison to western relaxation techniques like autogenic training. So far it has been established that the Indian techniques of relaxation like yoga and meditation are very effective in generating low frequency rhythms in the skin perfusion as monitored by optical sensors. According to medical experts, these low frequency rhythms have a very important bearing on the human physiology and have potential therapeutic implications. This book is meant to provide an overview of the current state-of-knowledge and encourage the next generation of scientists/engineers to carry this work forward, especially on the novel PPG application fields that are of growing importance like pain and stress assessment, detection of peripheral venous saturation and local arterio-venous oxygen consumption as well as contactless space resolved skin perfusion studies with modern camera based PPG technology.
Läs mer

Passa på att köpa kontorsmaterial

,

Hittills har vi återanvänt

 2 

 4 

 6 

 0 

 9 

 3 

 3 

böcker.

Trustpilot

Sveriges grönaste och skönaste bokhandel med den billigaste kurslitteraturen.

Detta är vår ambition och vi tummar inte på något för att nå dit. Vi finns till för att hjälpa studenter att spara och tjäna pengar på sin kurslitteratur samtidigt som vi tillsammans gör miljön en tjänst. Företaget startade våren 2005 av två studenter och har sedan dess strävat mot att ständigt göra det enklare att köpa och sälja begagnad kurslitteratur för så många som möjligt.

Prenumerera på vårt nyhetsbrev

Prenumerera för att ta del av våra bästa studenttips, erbjudanden och kampanjer.

Läs mer om hur vi hanterar persondata i vårt avsnitt om personuppgiftbehandling.

Passa på att köpa kontorsmaterial

Visa allt kontorsmaterial 👉
Söker...
Stäng